Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Clin Exp Vaccine Res ; 12(1): 60-69, 2023 Jan.
Article in English | MEDLINE | ID: covidwho-2266739

ABSTRACT

Purpose: Although the fast development of safe and effective messenger RNA (mRNA) vaccines against severe acute respiratory syndrome coronavirus 2 has been a success, waning humoral immunity has led to the recommendation of booster immunization. However, knowledge of the humoral immune response to different booster strategies and the association with adverse reactions is limited. Materials and Methods: We investigated adverse reactions and anti-spike protein immunoglobulin G (IgG) concentrations among health care workers who received primary immunization with mRNA-1273 and booster immunization with mRNA-1273 or BNT162b2. Results: Adverse reactions were reported by 85.1% after the first dose, 94.7% after the second dose, 87.5% after a third dose of BNT162b2, and 86.0% after a third dose of mRNA-1273. They lasted for a median of 1.8, 2.0, 2.5, and 1.8 days, respectively; 6.4%, 43.6%, and 21.0% of the participants were unable to work after the first, second, and third vaccination, respectively, which should be considered when scheduling vaccinations among essential workers. Booster immunization induced a 13.75-fold (interquartile range, 9.30-24.47) increase of anti-spike protein IgG concentrations with significantly higher concentrations after homologous compared to heterologous vaccination. We found an association between fever, chills, and arthralgia after the second vaccination and anti-spike protein IgG concentrations indicating a linkage between adverse reactions, inflammation, and humoral immune response. Conclusion: Further investigations should focus on the possible advantages of homologous and heterologous booster vaccinations and their capability of stimulating memory B-cells. Additionally, understanding inflammatory processes induced by mRNA vaccines might help to improve reactogenicity while maintaining immunogenicity and efficacy.

2.
Clin Exp Vaccine Res ; 11(1): 121-124, 2022 Jan.
Article in English | MEDLINE | ID: covidwho-1716131

ABSTRACT

Knowledge about mRNA-1273 elicited T-cell response is limited. We investigated adverse reactions and interferon gamma release by specific T-cells among mRNA-1273 vaccinated health care workers. Seven to 13 weeks after complete vaccination low levels of specific T-cells were detected not correlating with antibody response. Severity of symptoms after first and number of symptoms after second immunization were associated with T-cell response. Assessment of T-cell response in addition to antibody response is crucial because even few specific T-cells could add to protection against infection. Investigation of mRNA-1273 induced inflammatory processes might help improve reactogenicity and immunogenicity.

3.
Clin Exp Vaccine Res ; 11(1): 96-103, 2022 Jan.
Article in English | MEDLINE | ID: covidwho-1716128

ABSTRACT

PURPOSE: Studies on the immune responses to severe acute respiratory syndrome coronavirus 2 vaccines are necessary to evaluate the ongoing vaccination programs by correlating serological response data and clinical effectiveness data. We performed a longitudinal immunological profiling of health care workers vaccinated with mRNA-1273 (Moderna, Cambridge, MA, USA). Half of these vaccinees had experienced a mild coronavirus disease 2019 (COVID-19) infection in the spring of 2020 ("COVID-recovered" cohort), whereas the other half of the vaccinees had no previous COVID-19 infection ("COVID-naive" cohort). MATERIALS AND METHODS: Serum was drawn at multiple time points and subjected to assays measuring anti-Spike immunoglobulin G (IgG), avidity of anti-Spike IgG, avidity of anti-receptor binding domain (RBD) IgG, virus neutralizing activity, and interferon-γ release from stimulated lymphocytes. RESULTS: Between both cohorts and within each cohort, we found remarkable inter-individual differences regarding cellular and humoral immune responses to the Moderna mRNA-1273 vaccine. CONCLUSION: First, our study indicates that the success of mRNA-1273 vaccinations should be verified by serological assays in order to identify "low-responders" to vaccination. Second, the kinetics of anti-S IgG and neutralizing activity correlate well with clinical effectiveness data, thus explaining incipient protection against infection 2 weeks after the first dose of mRNA-1273 in COVID-naive vaccinees. Third, our IgG-avidity data indicate that this incipient protection is mediated by low-avidity anti-RBD IgG and low-avidity anti-S IgG.

5.
J Virol Methods ; 298: 114295, 2021 12.
Article in English | MEDLINE | ID: covidwho-1540812

ABSTRACT

Current studies focus on cellular and humoral immunity induced by novel SARS-CoV-2 vaccines. Non-responders to vaccinations are not uncommonly encountered in clinical medicine (e.g. in the field of hepatitis B). Whereas vaccine-induced humoral immunity against SARS-CoV-2 is compromised by emerging Variants of Concern (VOCs), cellular immunity against SARS-CoV-2 is emerging as resilient against VOCs. Thus commercially available test kits for diagnostic laboratories designed to evaluate cellular immune responses to SARS-CoV-2 are urgently needed. Here we evaluated the novel QuantiFERON SARS-CoV-2 assay (Qiagen) measuring INF-É£ release induced by two spike-derived peptide pools (Ag1 and Ag2) in a cohort of health care workers vaccinated with the mRNA-1273 vaccine and confirmed humoral response. Our study indicates the usefulness of this novel assay for routine laboratories to evaluate cellular immunity against SARS-CoV-2 in response to mRNA-1273 vaccination.


Subject(s)
COVID-19 , SARS-CoV-2 , 2019-nCoV Vaccine mRNA-1273 , Antibodies, Viral , COVID-19 Vaccines , Health Personnel , Humans , Interferon-gamma Release Tests , RNA, Messenger/genetics
6.
J Virol Methods ; 299: 114297, 2022 01.
Article in English | MEDLINE | ID: covidwho-1433622

ABSTRACT

BACKGROUND: Due to large vaccination efforts with novel vaccines there is an increasing need for laboratory tests assessing successful immunizations with SARS-CoV-2 vaccines. Unfortunately classical neutralization assays are laborious, time-consuming and require an adequate biosafety level laboratory. Recently, convenient ELISA-based surrogate neutralization assays (sVNTs) for determination of neutralizing SARS-CoV-2 antibodies have been developed. STUDY DESIGN: Our study compares the two novel ELISA-based SARS-CoV-2 surrogate neutralization assays "cPass SARS-CoV-2 Surrogate Virus Neutralization Test Kit" (GenScript Biotech, USA) and the "TECO SARS-CoV-2 Neutralization Antibody Assay" (TECOmedical, Switzerland) using 93 sera drawn from health care workers (HCVs) 2-3 weeks following the second vaccination with mRNA-1273 and 40 control sera from the pre-SARS-CoV-2 era before 2019. RESULTS: We found a sensitivity of 100% and 91,4% and a specificity of 100% and 100% for the GenScript assay and the TECO assay, respectively. Both sVNTs show a high correlation with anti-S IgG. Moreover, both sVNTs correlate well with each other. CONCLUSIONS: Surrogate neutralization assays based on the RBD as bait feature a high specificity and sensitivity for identifying humoral neutralizing activity in individuals vaccinated with the spike-based vaccine mRNA-1273. Although these assays appear well-suited for confirming successful vaccinations with spike-based vaccines, additional studies should compare both assays regarding other purposes such as screening COVID-recovered patients or individuals vaccinated with inactivated whole virus vaccines.


Subject(s)
COVID-19 , SARS-CoV-2 , Antibodies, Neutralizing , Antibodies, Viral , COVID-19 Vaccines , Humans , Immunization , Neutralization Tests , Spike Glycoprotein, Coronavirus , Vaccination
7.
J Virol Methods ; 288: 114024, 2021 02.
Article in English | MEDLINE | ID: covidwho-939115

ABSTRACT

There is an ongoing need for reliable antigen assays for timely and easy detection of individuals with acute SARS-CoV-2 infection. Using 75 swabs from patients previously tested positive by SARS-CoV-2 PCR and 75 swabs from patients previously tested negative by SARS-CoV-2 PCR, we investigated the sensitivity and specificity of the SARS-CoV-2 Rapid Antigen Test (Roche). We determined a specificity of 96 %. The assay's sensitivity with samples with a cycle threshold of < 25, 25 - <30, 30 - <35, and> = 35 was 100 %, 95 %, 44.8 % and 22.2 %, respectively. We conclude that sensitivity and specificity of the antigen assay is inferior to the PCR assay. However, the antigen assay may be a quick and easy to perform alternative for differentiation of individuals contagious for SARS-CoV-2 from non-contagious individuals.


Subject(s)
COVID-19 Testing/methods , COVID-19/diagnosis , Immunoassay , Reagent Kits, Diagnostic , Reverse Transcriptase Polymerase Chain Reaction , SARS-CoV-2 , Antigens, Viral/immunology , COVID-19/virology , COVID-19 Testing/standards , Humans , RNA, Viral , SARS-CoV-2/genetics , SARS-CoV-2/immunology , Sensitivity and Specificity
8.
J Virol Methods ; 287: 113978, 2021 01.
Article in English | MEDLINE | ID: covidwho-786044

ABSTRACT

There is an ongoing need for highly reliable serological assays to detect individuals with past SARS-CoV-2 infection. Using 75 sera from patients tested positive or negative by SARS-CoV-2 PCR, we investigated the sensitivity and specificity of the Liaison SARS-CoV-2 S1/S2 IgG assay (DiaSorin), the Elecsys Anti-SARS-CoV-2 assay (Roche), and the ID Screen SARS-CoV-2-N IgG indirect kit (IDVet). We determined a sensitivity of 95.5 %, 95.5 %, and 100 % and a specificity of 90.5 %, 96.2 %, and 92.5 % for the DiaSorin assay, the Roche assay, and the IDVet assay, respectively. We conclude that serologic assays combining very high sensitivity and specificity are still not commercially available for SARS-CoV-2. For maximizing sensitivity and specificity of SARS-CoV-2 serological diagnostics, the combination of two assays may be helpful.


Subject(s)
COVID-19 Serological Testing/methods , COVID-19/blood , SARS-CoV-2/immunology , Antibodies, Viral/blood , Humans , Immunoassay , Immunoglobulin G/blood , Sensitivity and Specificity
9.
Non-conventional | WHO COVID | ID: covidwho-268930

ABSTRACT

BACKGROUND: Facing the ongoing pandemic caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), there is an urgent need for serological assays identifying individuals with past coronavirus disease 2019 (COVID-19). STUDY DESIGN: Our study is the first to compare four new commercially available assays using 75 sera from patients tested positive or negative by SARS-CoV-2 PCR: the anti SARS-CoV-2 ELISA (IgG) (Euroimmun, Germany), the EDI New Coronavirus COVID-19 IgG ELISA, (Epitope diagnostics (EDI), USA), the recomWell SARS-CoV-2 IgG ELISA (Mikrogen, Germany), and the SARS-CoV-2 Virachip IgG (Viramed, Germany). RESULTS: We found a sensitivity of 86.4 %, 100 %, 86.4 %, and 77.3 % and a specificity of 96,2 %, 88,7 %, 100 %, and 100 % for the Euroimmun assay, the EDI assay, the Mikrogen assay, and the Viramed assay, respectively. CONCLUSIONS: Commercially available SARS-CoV-2 IgG assays have a sufficient specificity and sensitivity for identifying individuals with past SARS-CoV-2 infection.

SELECTION OF CITATIONS
SEARCH DETAIL